Safety Manager | FC-/FS- Series

The Honeywell Safety Manager stands as a robust safety control platform, prioritizing safety in industrial process control applications. As the core of a safety instrumented system (SIS), it safeguards personnel, equipment, and the environment through swift action in response to process deviations. Here's a comprehensive overview of its capabilities:

Core Functionalities:

  1. Safety Logic Execution: Executes pre-programmed safety logic, dictating system actions when critical process variables surpass safe limits.
  2. Communication and Monitoring: Interfaces with diverse field devices and process I/O modules, monitoring parameters such as pressure, temperature, and flow.
  3. Safe State Activation: Identifies safety hazards and responds by triggering emergency shutdowns, activating safety interlocks, or sounding alarms to mitigate risks.
  4. Diagnostics and Self-Testing: Conducts ongoing self-diagnostics to ensure system functionality and reliability.

Benefits of Using Honeywell Safety Manager:

  1. Enhanced Safety: Significantly reduces the risk of accidents and injuries in industrial operations.
  2. Compliance with Safety Standards: Facilitates adherence to rigorous safety standards like IEC 61508, vital across various industries.
  3. Improved Plant Reliability: Prevents safety incidents and equipment damage, leading to increased plant uptime and operational efficiency.
  4. Reduced Risk and Liability: Deployment of a robust SIS minimizes the likelihood of accidents and potential liabilities for companies.

The Honeywell Safety Manager serves as a pivotal component in ensuring safety and operational integrity within industrial environments, providing peace of mind and regulatory compliance to stakeholders.

Potential Meaning of FC-/FS- Series:

  • FC- Series: These modules focus on "Fieldbus Communication," enabling the Safety Manager to communicate with process I/O devices on specific fieldbus protocols like Profibus or Foundation Fieldbus.
  • FS- Series: Modules within the "FS- Series" are specialized for "Fail-Safe" applications, enhancing safety logic execution.

81 products

Sort
Sort

81 products

Sale

Sale

FC-TELD-0001 | Honeywell UIO EARTH LEAKAGE SENSOR 24VDC FC-TELD-0001 | Honeywell UIO EARTH LEAKAGE SENSOR 24VDC

Sale

Sale

FS-SICC-1011/L15 RUSIO SIC cCable to Female Sub | Honeywell PLC

Sale

Sale

FC-TSRO-08UNI | Honeywell | FTA Module FC-TSRO-08UNI | Honeywell | FTA Module

Sale

Sale

Honeywell FC-IOTA-R24 Redundant IO Termination Assembly PLC Honeywell FC-IOTA-R24 Redundant IO Termination Assembly PLC

Sale

Sale

FC-FANWR-24R | Honeywell Fan Assembly Kit FC-FANWR-24R | Honeywell Fan Assembly Kit

Sale

Sale

FC-SDIL-1608 Module | Honeywell Safety Manager System FC-SDIL-1608 Module | Honeywell Safety Manager System

Sale

Sale

Honeywell S300 FC-TCNT11 Redundant IOTA Module Honeywell S300 FC-TCNT11 Redundant IOTA Module

Sale

Sale

FC-SCNT01 | Honeywell S300 51454926-176 Safety Controller Module FC-SCNT01 | Honeywell S300 51454926-176 Safety Controller Module

Sale

Sale

Honeywell FS-PDB-CPX05 Power Distribution Board Controller Cabinet

Sale

Sale

FC-PSU-UNI2450U Honeywell Power Supply PSU 115/230VAC 24Vdc 50A FC-PSU-UNI2450U Honeywell Power Supply PSU 115/230VAC 24Vdc 50A

Sale

Sale

New Honeywell FC-BKM-0001 Battery and Key Switch Module New Honeywell FC-BKM-0001 Battery and Key Switch Module

Sale

Sale

FC-QPP-0002 | Honeywell Quad Processor Module FC-QPP-0002 | Honeywell Quad Processor Module

Sale

Sale

Honeywell FC-QPP-0001 Quad Processor Pack Honeywell FC-QPP-0001 Quad Processor Pack

Sale

Sale

Honeywell FC-SAI-1620M Safe High-Density Analog Input Module Honeywell FC-SAI-1620M Safe High-Density Analog Input Module
Local Pickup Available